|              設(shè)備的額定電流             A              |                          zui小導(dǎo)體尺寸              |         |
|              標(biāo)稱截面積             mm2              |                          AWG或kcmil             [截面積mm2](見注2)              |         |
|              ≤6              |                          0.751)              |                          18 [0.8]              |         
|              ??~≤10              |                          (0.75)2)   1.00              |                          16 [1.3]              |         
|              ????~≤13              |                          (1.0)3) 1.25              |                          16 [1.3]              |         
|              ???~≤16              |                          (1.0)3) 1.5              |                          14 [2]              |         
|              ???~≤25              |                          2.5              |                          12 [3]              |         
|              ???~≤32              |                          4              |                          10 [5]              |         
|              ???~≤40              |                          6              |                          8 [8]              |         
|              ???~≤63              |                          10              |                          6 [13]              |         
|              ???~≤80              |                          16              |                          4 [21]              |         
|              ???~≤100              |                          25              |                          2 [33]              |         
|              ????~≤125              |                          35              |                          1 [42]              |         
|              ????~≤160              |                          50              |                          0 [53]              |         
|              ????~≤190              |                          70              |                          000 [85]              |         
|              ????~≤230              |                          95              |                          0000 [107]              |         
|              ????~≤260              |                          120              |                          250 kcmil [126]              |         
|              ????~≤300              |                          150              |                          300 kcmil [152]              |         
|              ????~≤340              |                          185              |                          400 kcmil [202]              |         
|              ????~≤400              |                          240              |                          500 kcmil [253]              |         
|              ????~≤460              |                          300              |                          600 kcmil [304]              |         
|              1、如果軟線的長度不超過2m,則括號中的數(shù)值適用于裝有符合GB 17465(C19、C21和C23型)規(guī)定的額定值為16A的連接器的可拆卸電源軟線。             2、如果軟線的長度不超過2m,則括號中的數(shù)值適用于裝有符合GB 17465(C13、C15、C1和C17型)規(guī)定的額定值為10A的連接器的可拆卸電源軟線。             3、 對額定電流小于3A,如果軟線的長度不超過2m,允許標(biāo)稱截面積為0.5mm2。             注:             1 、GB 17465規(guī)定了器具耦合器和軟線的連接方式,包括條件1)、條件2)和條件3)所提到的連接方式,但是,許多國家已經(jīng)指出,對表3B中列出的所有的值,特別是條件1),2)3)所包括的內(nèi)容,他們不接受。             2、所提供的AWG和kcmil尺寸僅供參考,括號中的相關(guān)截面積僅給出經(jīng)圓整的有效數(shù)。AWG是美國線規(guī),術(shù)語“cmil”系指圓密耳。1個圓密耳等于直徑為1密耳(千分之一英寸)的圓面積。這些術(shù)語通常在北美用于說明導(dǎo)線的尺寸。              |         ||